For Exclusive Savings
Follow Us!
Click for the BBB Business Review of this Soldering Equipment in Bound Brook NJ

Official PayPal Seal
Secured by PayPal

  Home > ESD Static Control > Desco Industries Brand > Wrist Straps and Coil Cords > Desco Single-Wire Straps & Coil Cords > Adjustable Elastic Wrist Straps >

  Desco 09025 - ESD Elastic Wristband, Blue, Small 4mm

Desco 09025 ESD Wristband, Bue, Small, 4mm Snap Elastic


 
Desco Industries
Authorized ESD Specialist & Distributor
Manufacturer Price: $8.57
Price: $7.05
You Save: $1.52!

Quantity in Stock :12
Availability: Factory Stock; Usually Ships in 1 Week
Part #: DESCO-09025
Quantity:

Product Description
 
Desco 09025 is an antistatic, ESD safe Light Blue Wristband Elastic, Small 4 mm.  Band only, size small, 5" minimumm 9" maximum and a width of 1.125".

Product Advanced Details:
A. Cap - ABS plastic, blue, with teeth to hold knitted material during bonding.
B. 300 series stainless steel backplace (.016" thick). Provides 1.4 sq in. of skin contact surface. Manufacturing date code is stamped into stainless steel backplace
C. 4mm sna stud machined from 300 series stainless steel.  Fits to 4mm spring loaded medical type socket.  Coil cord disengages from snap with 1-5 lbs of perpendicular dorce, fulfilling ESD-S1 paragraph 4.1.6 breakaway force requirement.  Durable, providing long life well beyond that of sheet metal snaps.
D. Knit elastic band material of light blue fiber. 1.125" (32 mm) wide and 0.10" (2.54 mm) thick, 65 strands of textured polyester, 46 strangs of lycra spandex and 14 strangs of silver plated polyproplyene yarn.  Made with pure silver irreversibly bound to fibers providing both antimicrobial and anti-odor performance.  Outer surface of light blue fibers act as an insulator
E. The conductive silver plated polypropylene (see D) represents 14.5% of the material by weight.  The 14 strands of conductive polyproplene are uniformly knit on the innter surface of the material and are electrically isolated from the outer surface (blue side).
F. Desco, item # and Made in the USA are molded into cap
G. Meets or exceeds requirements of ANSI ESD-S20.20 and EOS/ESD-S1-1987

This product comes in the additional variations:
Desco 09026 - Band Only, Minimum - Medium 6" (152 mm), Maximum - 11" (280 mm), Width - 1.125" (32 mm)
Desco 09027 - Band Only, Minimum - Large 6.5" (165 mm), Maximum 12" (305 mm), Width - 1.125" (32 mm)


Fixed sized bands available in three sizes (small, medium, large)
Easy to use - no adjustment necessary. Three sizes provide an excellent fit for most people 
Extra wide, soft elastic band
Increased wearer comfort 
Has silver impregnated polypropylene knitted on inside for superior conductivity
Reliably removes generated static charges 
Made with pure silver irreversibly bound to fibers providing both antimicrobial and anti-odor performance
Locking clasp
Band locked so it will not slip 
Medical grade 300 series stainless steel used for all metal parts
Eliminates allergic skin reactions for most people 
Non-shedding, non-sloughing band material
Safe for microelectronics 
One Megohm Series Resistor 
To protect operator from accidental contact with equipment line voltage. 
UL listed
Independent review of the adequacy of the product's design. 
Date coded
Providing lot traceability to ensure quality control 
Made in the United States of America

What the ESD Association says about testing wrist straps:
Per ESD Handbook TR20.20 section 5.3.9.1 Wrist Strap Checkers - "Wrist strap checkers have historically been the primary tool for testing the operation of the wrist strap system including, the wristband, grounding cord, and most importantly, the electrical integrity of the contact between the wristband and the wearer.  Wrist strap checkers measure the resistance of the entire system."
Circumference - 2.5" - 13"

Note: All bands have a 4mm snap stud.  Complete wrist strap kits include an alligator clip.  Wrist strap kits include an alligator clip for occasions when a grounded banana jack is not available.  However, best industry practice is that ESD Ground Connections should be firm fitting connecting devices such as metallic crimps, snaps and bana plugs to be connected to designated ground points.  Use of alligator clips is not recommended. (Ref: JEDEC Standard No. 625-A)

ANSI/ESD S20.20 Paragraph 6.2.2.1 Personnel Grounding Requirement " ALl personnel shall be bonded or electrically connected to ground of contrived ground when handling ESD sensitive tems.  When personnel are seated at ESD protective workstations, they shall be connected to the common point via a wrist strap system."



All prices subject to change without notice. Prices advertised are for online orders only.
Shipping and/or international duties/taxes are separate. Stock availability can change at any time.

Be the first to write a review.



ESD Static Control > Desco Industries Brand > Wrist Straps and Coil Cords > Desco Single-Wire Straps & Coil Cords > Adjustable Elastic Wrist Straps
ESD Static Control > Desco Industries Brand > Wrist Straps and Coil Cords > Desco Single-Wire Straps & Coil Cords
ESD Static Control > Desco Industries Brand
ESD Static Control
ESD Static Control > ESD Wrist Straps
ESD Static Control > Desco Industries Brand > Wrist Straps and Coil Cords